SYRINGES From SGE,
SYRINGES
from SGE, Inc.
SGE has introduced the new Series II
syringe range, the next generation of analytical syringes.
New materials, design modifications and production methods
have been introduced to ensure that the Series II syringes
give the best quality and long life performance that modern
syringe technology can provide. Series II syringes have the
following features:
- New packaging, order codes and
part numbers
- All Series II syringes are fitted
with an oval anti-roll flange
- Removeable needle syringes have a
new seal design (solid PTFE)
- Simplified repair and needle
replacement
Note: All fixed needle syringes are
available in removeable needle versions. Please inquire for
more information if you have this need.
| Various needle styles
are available for a wide range of applications.
Styles other than those listed below are available.
Please inquire for more information. |
| Style
#1 Cone needle tip. This style has been developed
to withstand the multiple injection demands of
autosamplers. They are also standard on microvolume
and Jade valve syringes and recommended with
predrilled septa. |
| Style
#2 Bevel needle tip. A 20º bevel tip is the
standard general purpose needle tip style supplied
with SGE syringes. It is designed for optimum septum
penetration and to prevent septum coring. |
SGE manufactures many other
syringes and space does not permit us to list them all. If
you are using an SGE syringe not listed above, contact us
with the SGE part number and we will obtain it for you.
MICROVOLUME
SYRINGES (REMOVEABLE NEEDLE)
SGE's plunger-in-needle syringes combine
maximum accuracy with rugged, durable construction. Because
the plunger extends into the needle, 100% of the sample is
dispensed. The very fine plunger wire of the 0.5uL and 1uL
syringes is uniquely protected by a strong sheath and guide
tube. The needles and plungers are easily removed for
cleaning and replacement.
| |
Needle Specifications (mm) |
|
|
| |
Length |
OD |
ID |
Style #
|
Part
# |
Price |
| 0.5uL
(6.5mm O.D. barrel) |
50 |
0.63 |
0.15 |
1 |
SYR-00300 |
$55.00 |
| Replacement
needle/ plunger kit |
|
|
|
|
SYR-33010 |
$17.00 |
| 1.0uL
(8mm O.D. barrel) |
70 |
0.63 |
0.15 |
1 |
SYR-0505 |
$43.00 |
| Replacement
needle/ plunger kit |
|
|
|
|
SYR-34057 |
$17.00 |
PLUNGER
PROTECTION SYRINGES (FIXED NEEDLE)
Plunger protected syringes means no more
bent plungers or buttons. Accurate and reproducible to within
1%. Clear and sharp graduations.
| |
Needle Specifications (mm) |
|
|
| |
Length |
OD |
ID |
Style
# |
Part
# |
Price |
| 10uL
(6.5mm O.D. barrel) |
50 |
0.47 |
0.11 |
2 |
SYR-02000 |
$19.80 |
| 10ul
(Six pack) |
|
|
|
|
SYR-02030 |
$100.00 |
SUPERFLEXTM
SYRINGES (FIXED NEEDLE)
SGE's super elastic alloy plungers combined
with the patented plunger protection guide and button
reinforcement ensures precise and smooth injections. These
new technology plungers return to their original shape even
if bent or twisted, and with the added SGE features, are over
5 times more rigid over other competitive flexible plunger
syringes.
| |
Needle Specifications (mm) |
|
|
| |
Length |
OD |
ID |
Style
# |
Part
# |
Price |
| 10uL |
50 |
0.47 |
0.11 |
2 |
SYR-02100 |
$23.00 |
| 10ul
(Six pack) |
|
|
|
|
SYR-02130 |
$120.00 |
GUIDED
PLUNGER SYRINGES (FIXED NEEDLE)
The guided plunger syringe line has
overcome the problem of bend plungers commonly associated
with low volume syringes. The extended barrel and reinforced
plunger provide a rugged syringe
| |
Needle Specifications (mm) |
|
|
| |
Length |
OD |
ID |
Style #
|
Part
# |
Price |
| 5uL
(8mm O.D. barrel) |
50 |
0.47 |
0.11 |
2 |
SYR-01400 |
$37.00 |
| 10uL
(8mm O.D. barrel) |
50 |
0.47 |
0.11 |
2 |
SYR-02400 |
$45.00 |
GAS TIGHT
SYRINGES
The gas tight syringes are suitable for
both gas and liquid samples where inertness is important. All
plungers are replaceable and are fitted with precision
machined teflon tips.
| |
Needle Specifications (mm) |
|
| |
Length |
OD |
ID |
Style
# |
Part
# |
Price |
| Fixed needle |
| 10uL |
50 |
0.47 |
0.11 |
2 |
SYR-02200 |
$26.00 |
| Replacement
plunger |
|
|
|
|
SYR-31810 |
$20.00/2 |
| 25uL |
50 |
0.50 |
0.20 |
2 |
SYR-03200 |
$26.00 |
| Replacement
plunger |
|
|
|
|
SYR-31815 |
$15.00 |
| 50uL |
50 |
0.50 |
0.20 |
2 |
SYR-04200 |
$28.00 |
| Replacement
plunger |
|
|
|
|
SYR-31820 |
$15.00 |
| 100uL |
50 |
0.50 |
0.20 |
2 |
SYR-05200 |
$28.00 |
| Replacement
plunger |
|
|
|
|
SYR-31825 |
$15.00 |
| 250uL |
50 |
0.50 |
0.20 |
2 |
SYR-06200 |
$30.00 |
| Replacement
plunger |
|
|
|
|
SYR-31830 |
$15.00 |
| 500uL |
50 |
0.50 |
0.20 |
2 |
SYR-07200 |
$30.00 |
| Replacement
plunger |
|
|
|
|
SYR-31835 |
$15.00 |
| Removeable needle |
| 1ml |
50 |
0.63 |
0.32 |
2 |
SYR-08100 |
$46.00 |
| Replacement
plunger |
|
|
|
|
SYR-31840 |
$22.00 |
| Replacement
needles (pkg. 5) |
|
|
|
|
SYR-39110 |
$12.00/ 5 |
| 2.5ml |
50 |
0.63 |
0.32 |
2 |
SYR-08500 |
$46.00 |
| Replacement
plunger |
|
|
|
|
SYR-31850 |
$22.00 |
| Replacement
needles (pkg. 5) |
|
|
|
|
SYR-39110 |
$12.00/ 5 |
AUTOSAMPLER
SYRINGES
SGE autosampler syringes are designed and
tested to meet critical autosampler specifications. The
unique plunger design eliminates bending and seizing and the
needle point style was designed specifically to withstand
multiple and fast septum injections.
| |
Needle Specifications (mm) |
|
| |
Gauge |
OD |
ID |
Style #
|
Part
# |
Price |
| Hewlett-Packard (Fixed needle) |
| HP-7673
5uL |
26 |
0.47 |
0.11 |
1 |
SYR-01800 |
$45.00 |
| HP-7673
5uL (Six pack) |
|
|
|
|
SYR-01804 |
$264.00 |
| HP-7673
5uL |
26 |
0.63 |
0.11 |
1 |
SYR-01810 |
$45.00 |
| HP-7673
5uL (Six pack) |
|
|
|
|
SYR-01814 |
$264.00 |
| HP-7673
10uL |
26 |
0.47 |
0.11 |
1 |
SYR-02800 |
$29.00 |
| HP-7673
10uL (Six pack) |
|
|
|
|
SYR-02804 |
$168.00 |
| HP-7673
10uL |
26 |
0.63 |
0.11 |
1 |
SYR-02810 |
$29.00 |
| HP-7673
10uL (Six pack) |
|
|
|
|
SYR-02814 |
$168.00 |
| HP-7673
10uL gas tight |
23 |
0.63 |
0.11 |
1 |
SYR-02812 |
$32.00 |
| Perkin
Elmer |
| Autosystem
0.5uL (removeable needle) |
26 |
0.47 |
0.15 |
1 |
SYR-00475 |
75.00 |
| Replacement
needle |
|
|
|
|
SYR-33750 |
17.00 |
| Autosystem
0.5uL (removeable needle) |
23 |
0.63 |
0.15 |
1 |
SYR-00478 |
75.00 |
| Replacement
needle |
|
|
|
|
SYR-33765 |
17.00 |
| Autosystem
5uL (fixed needle) |
26 |
0.47 |
0.11 |
1 |
SYR-01955 |
55.00 |
| Autosystem
5uL (fixed needle) |
23 |
0.63 |
0.11 |
1 |
SYR-01957 |
55.00 |
| Varian |
| Varian
8035,8100 10uL (Removeable needle) |
25 |
0.5 |
0.15 |
2 |
SYR-02924 |
125.00 |
| Replacement
needle - 8035 |
|
|
|
|
SYR-37776 |
21.00/
2 |
Home Page
Quadrex Corporation
P.O. Box 3881
Woodbridge, CT. 06525 U.S.A.
Telephone: (203) 393-3112; (800) 275-7033
FAX: (203) 393-0391
Send mail to Webmaster@quadrexcorp.com with questions or comments about this web site.
Copyright © Quadrex Corporation
Web Site Designed By Bob White From Duet Productions Ltd.
" We are not affiliated in any way with the Quadrex Corporation (symbol: QUAD) that is traded on the stock market. "
|