HIGH PURITY
NITROGEN GENERATORS

99.9995% PURITY
These High Purity Nitrogen systems are designed to run 24 hours a day, 7 days a week and include a built-in air compressor.  They utilize a "Pressure Swing Adsorption" (PSA) method to extract pure nitrogen from air.  Unwanted gases are selectively adsorbed from compressed air into a column containing porous carbon molecular sieve material.  The Peak Nitrogen Generators use a unique single column system where the column is alternately pressurized and vented under a finely tuned timing cycle.  This guarantees high purity better than similarly sized 2-column systems.
CATALOG No. GGS-NG250A GGS-NG600A GGS-NG1000A GGS-NG2000A GGS-NG3000A GGS-NG4000A
Max. Output Flow Rate 250cc/ min 600cc/ min. 1000cc/ min. 2000cc/min. 3000cc/ min. 4000cc/ min.
Purity 99.9995% 99.9995% 99.9995% 99.9995% >99.9995% >99.9995%
Pressure Dewpoint -100F -100F -100F -100F -100F -100F
Max. Delivery Pressure 80 psig 80 psig 80 psig 80 psig 80 psig 80 psig
Electrical Requirements (110V) 5.0 amps 5.0 amps 6.0 amps 6.0 amps 6.0 amps 6.0 amps
Dimensions 31"x13"x13" 31"x13"x13" 53"x22"x27" 53"x22"x27" 53"x22"x27" 53"x22"x27"
Shipping weight 190 lbs 190 lbs 190 lbs 240 lbs 240 lbs 240 lbs
Price $5,000.00 $6,150.00 $7,125.00 $9,850.00 $12,550.00 $13,550.00


HIGH OUTPUT
NITROGEN GENERATORS
FOR LC/MS SYSTEMS
in APCi or ESi MODES


UP TO 30 LITERS PER MIN. WITH >95% purity *
The Peak High Output Nitrogen Generators use hollow fiber membrane technology to efficiently separate nitrogen from other gases in air to produce a continuous high flow supply of high purity nitrogen for use in LC/MS systems using either APCi or ESi modes. The Peak High Output Nitrogen Generators are easy to use, install in minutes, come with a built-in filtration system and with or without the built-in air compressor.

FEATURES AND BENEFITS
ÙBuilt in air compressor: Optional ÙDry Nitrogen: -70°C / -94ºF PDP
ÙEasy installation: "Plug and Play" No special installation required Ù24 hour supply: Continuous gas supply
ÙPurity: Constant purity with no fall off in performance. ÙQuiet: Locate directly in the lab
ÙSafe and cost effective: Replace cylinders ÙMobile: Move to suit your requirements
ÙExperience: Over 10,000 systems worldwide using this technology ÙDesign: Specifically for LC/MS/MS

Recommended and used with Applied Biosystems/MDS Sciex, Finnigan/Thermoquest, LECO, Micromass, Waters, H-P & Shimadzu LC/MS systems.

ADVANTAGES OF PEAK vs. OTHER NITROGEN GENERATOR MANUFACTURERS
Ù   Built-in Air Compressor: Peak offers self contained systems with complete independence from house air sources, and the fluctuation in pressure that can occur. Incoming air pressure fluctuation affects purity and flow.
Ù Mass Flow Controller: Peak utilizes mass flow controllers to ensure that every system maintains purity levels.
Ù Wider product range: The Nitrogen Generators manufactured by Peak Scientific come in a wide range of output levels. Whatever your purity or flow requirements, Peak will build a generator to suit your needs.


Required LC/MS Flow Rates by brand name
(Not all brands or models shown)
LC/MS Mfg./Model or Mode Flow Pressure Recommended Generator
Micromass
APCI mode 30 Liters/min. 100psi NM30L or NM30LA
ESi Mode 16 Liters/min. 100psi NM18L or NM18LA
H-P 1100

Ion Trap Mode

13 Liters/min. 100psi

NM18L or NM18LA

Thermoquest
TSQ7000 5 Liters/min. 100psi NM18L or NM18LA
LCQ700 5 Liters/min. 100psi NM18L or NM18LA
Deca 30 Liters/min. 100psi NM30L or NM30LA
Duo 30 Liters/min. 100psi NM30L or NM30LA
NOTE: Deca and Duo are probe dependent.
API with one probe requiers 18-20 L/min. API with two probes requires 30 L/min.
Finnigan
Navigator 13 Liters/min. 100psi NM18L or NM18LA
AQA 10 Liters/min. 80 psi NM18L or NM18LA


CATALOG No. GGS-NM18L GGS-NM18LA GGS-NM30L GGS-NM30LA
Max Flow Rate (ATP) 18 liters/ min. 18 liters/ min. 30 liters/ min. 30 liters/ min.
Outlet Pressure input dependent input dependent input dependent input dependent
Built-in Air Compressor no yes no yes
Purity * See Purity Statement below *
Nitrogen Pressure Dewpoint -70ºC / -94ºF -70ºC / -94ºF -70ºC / -94ºF -70ºC / -94ºF
Particles >0.01 um none none none none
Suspended Liquids none none none none
Phthalates none none none none
Min-Max Air Inlet Pressure 110 - 150 psi n/a 110 - 150 psi n/a
Maximum Ambient
OperatingTemperature
37ºC / 98ºF 37ºC / 98ºF 37ºC / 98ºF 37ºC / 98ºF
Noise Level none <53 dB (A) 3 ft. none <53 dB (A) 3 ft.
Electrical Requirements
(220V available upon request)
none 110V 60 Hz none 110V 60 Hz
Dimensions (HxWxD) 30"x10"x6.5" 34.6"x17"x16" 30"x10"x6.5" 36"x24"x24"
Weight 22 lbs 90 lbs 29 lbs 198 lbs
Price $8,650.00 $11,320.00 $9,680.00 $14,160.00

* PURITY STATEMENT *
Peak Scientific Instruments generators are tested under strict ‘factory controlled conditions’
against which the specifications are published. Nitrogen purity is tested and recorded as part of the QC test
but excluded from the specifications for the reasons given below.
 

Many environmental factors can affect purity such as
ambient temperature, barometric pressure, and altitude.
 In addition, nitrogen purity will also vary directly with the Output Pressure and Mass Flow requirements
 of the mass spectrometer. It is therefore very difficult to predict and guarantee
the exact purity of delivered nitrogen everywhere around the world.

Some generator manufacturers do quote specifications for purity and have chosen
to provide a table with conditions and caveats which make it equally difficult to work out what the real figure truly is.

These high volume nitrogen generators are specifically designed to satisfy the requirements of LC/MS/MS systems only
 and are approved and/or specified by many LC/MS/MS OEM manufacturers. 
In all the years of testing and collaboration
 with the MS instrument manufacturers, as well as thousands of satisfied users in over 70 countries,
nitrogen purity has never been an issue that affected MS performance or experimental results.

This is what is really important and testament to the fact that the nitrogen supplied
 by the 'NM' Nitrogen Generators will meet your LC/MS/MS needs

While these Generators may be used for other lab or industrial applications,
the output purity cannot be guaranteed.


Larger models with 60, 120, 180, and 240L/min. outputs are also available. Inquire for pricing.

Send mail to Webmaster@quadrexcorp.com with questions or comments about this web site.
Copyright © 2006 Quadrex Corporation
Web Site Designed By
Bob White From Duet Productions Ltd.  

" We are not affiliated in any way with the Quadrex Corporation (symbol: QUAD) that is traded on the stock market. "