SRI TO-14 AIR
MONITORING GC
|
|
The TO-14 GC includes: |
 |
PID detector |
 |
FID/DELCD combo detectors |
 |
TO-14
dual trap air concentrator |
 |
Built-in air compressor |
 |
Vacuum
pump with Peaksimple controlled
interface |
 |
4-channel
Peaksimple data system |
 |
60M.
Capillary Column |
|
 |
For TO-14
analysis and ambient air analyses of all
types, this GC configuration has
everything you need in a compact, easy
to transport package. Small enough to
take on-site for real time measurements,
you can avoid the need for expensive,
labor intensive canister sampling by
performing the analysis right at the
source.
By
comparing the relative response, the
three detectors make peak identification
and confirmation easy. The FID responds
to all hydrocarbons, the PID to selected
hydrocarbons, and the DELCD to halogens
only. The dual-trap sample concentrator
is similar to the SRI purge & trap but
has a gas inlet instead of a liquid
purge vessel ( the liquid purge head can
be added if required ). The innovative
dual-trap design results in more
efficient trapping and desorb than
single trap designs, especially for the
early eluting peaks such as vinyl
chloride.
The
built-in "whisper quiet" air compressor
eliminates the hassle of transporting
bulky air cylinders by providing an
endless supply of combustion air for the
FID/DELCD detector. The user need only
transport small cylinders of carrier and
hydrogen (or get the Stand-Alone SRI
Hydrogen Generator for both the FID fuel
and carrier gas!) which are used at a
much lower rate than air, thus a small
cylinder will last for weeks or months
of operation. The vacuum pump interface
allows the PeakSimple data system to
turn a vacuum pump ( not supplied ) on
and off under control of the software.
The vacuum pump is used to draw ambient
air through the traps for a precise
amount of time thus enabling the system
to sample unattended, The 60-meter
capillary column is the newest
unbreakable fused silica lined stainless
steel technology, and gives good
separation of the TO-14 analytes with
short run times.
The
PeakSimple data system controls and
sequences the entire analysis,
collecting data from the three
detectors, loading and desorbing the
traps, then printing and calculating the
results. Because all the A/D hardware is
inside the GC chassis and communicates
to your notebook or desktop PC through a
standard serial port cable, no boards
need to be installed in your computer.
|
|
|
|
#SRI-8610-0114-1,
TO-14 AIR MONITORING GC (110V) |
$23,169.00 |
|
#SRI-8610-0114-2,
TO-14 AIR MONITORING GC (220V) |
$23,169.00 |
|
Options
& Upgrades:
Additional TO-14 Air Concentrator, 6 channel
USB PeakSimple data system,
Split/Splitless and PTV injectors, additional columns
|
|
|