SRI GC INJECTORS

 
Up
SRI PRECONFIGURED GCs
SRI ACCESSORIES
SRI DETECTORS
SRI INJECTORS
SRI GC MAINFRAMES
SRI GC INJECTOR OPTIONS
Each SRI GC comes standard with one 1/8" cold on-column injector for use with either 0.53mm I.D. capillary or 1/8" packed columns, see below. This type of injector allows the sample to be deposited directly into the bore of the column and avoids any contact with the injector port surfaces. This eliminates the need for a heated injector and is ideal for 0.53mm I.D. capillary columns.
  • For solids, choose the Thermal Soil Desorber or the Heated Static Headspace.
  • For liquids, choose the Cold On-Column, Heated Flash On-Column, Heated Split/Splitless, or the Heated Static Headspace.
  • For gases, choose the 10 Port Gas Sampling Valve or the Purge and Trap.
  • Add automation with the Method 5030 Purge and Trap Autosampler, or the 42 Vial Liquid Autosampler.

Up to 5 injector types, covering solids, liquids and gases can be mounted simultaneously onto the Model 8610C GC mainframe.  Due to limited space, only one injector can be mounted on the Model 310 GC. Click on the links at right to go directly to the specific information on the available injector hardware.

Heated Flash Vaporization, Heated Split/Splitless and PTV injectors are all upgrades to the On-column injector. All injectors must be installed at the SRI factory.

SRI GC - INJECTOR OPTIONS

  HEATED SPLIT/ SPLITLESS INJECTOR (SOFTWARE ACTIVATED)  MORE INFORMATION
  HEATED 'FLASH' ON-COLUMN (1/ 4" PACKED COLUMN) INJECTOR  MORE INFORMATION
  ADD ONE OR MORE COLD ON-COLUMN INJECTORS  MORE INFORMATION
  PTV - PROGRAMMABLE TEMPERATURE VAPORIZER  MORE INFORMATION
  Heated Static Headspace Injector  MORE INFORMATION
  METHOD TO-14 AIR CONCENTRATOR with VACUUM PUMP INTERFACE  MORE INFORMATION
  EPA METHOD 5035 COMPLIANT PURGE AND TRAP  MORE INFORMATION
  PURGE AND TRAP AUTOSAMPLER (10 POSITION (110V or 220V)  MORE INFORMATION
  10 PORT GAS SAMPLING VALVE (ELECTRIC OR MANUALLY OPERATED)  MORE INFORMATION
  THERMAL SOIL DESORBER (ELECTRIC ACTUATOR)  MORE INFORMATION
  CRYO-COOLED PELTIER TRAP  MORE INFORMATION
 
Hot Tip
up to five injectors can be mounted on the 8610c gc mainframe.  due to limited space, only a single injector can be mounted on the 310 gc mainframe.

Hot Tip #2
in order to add a second injector, of any type, additional cold on-column injector hardware must be added first.  this hardware is then upgraded to the appropriate injector type.
 