SRI GC INJECTORS - EPA METHOD 5030/5035 PURGE AND TRAP

 
SRI PRECONFIGURED GCs
SRI ACCESSORIES
SRI DETECTORS
SRI INJECTORS
SRI GC MAINFRAMES
SRI EPA METHOD 5030/5035 PURGE AND TRAP
Built into the GC for lower dead volume and better peak shapes
No need for transfer lines
Two independently heated adsorbent traps
Complies with EPA Methods
Peaksimple control

The SRI Purge & Trap concentrates the volatile organic compounds (VOCs) in a gas, water, or soil sample onto two adsorbent traps, from which they are automatically desorbed onto the GC column. The Method 5030/5035 Compliant Purge & Trap is equipped with interchangeable purge heads. The 5035 purge head is a thermostatted (typically 40oC) 

sleeve which accepts standard 40mL VOA vials. The entire sleeve is mechanically agitated while purging to comply with the requirements of EPA Method 5035. The 5030 purge head uses low-cost, disposable 16mm test tubes which are purged at ambient temperature. For higher level soil samples or soil/methanol extractions, the test tube is more convenient and less expensive than VOA vials.

Operation of the Purge & Trap is completely automated by the PeakSimple data system that is built into the GC. Run parameters such as purge time, desorb heat, bake-out, vial temperature, and mechanical agitation are adjusted in a PeakSimple Event table.

The SRI Purge & Trap is unique because it is equipped with two traps rather than one.  Each trap can be heated independently at the adsorption temperature (typically 35-70oC), the desorption temperature (200oC), and the bake-out temperature (250oC). For most VOC applications, the first trap is Tenax-GR, and the second trap is Carbon Molecular Sieve. By setting the adsorption temperature of the Carbon MoleSieve to 50-60oC and the Tenax-GR to 35oC, water retention is dramatically reduced. By staggering desorption times, early eluting peaks from the hot Carbon MoleSieve trap are refocused on the temporarily cold Tenax-GR trap, resulting in much sharper peaks than otherwise possible

#SRI-8690-0052, Method 5030/5035 Compliant Purge and Trap
(with interchangeable purge heads)

$8,239.00

#SRI-8690-0051, Method 5030 Compliant Purge and Trap

$6,689.00
 
Hot Tip
up to five injectors can be mounted on the 8610c gc mainframe.
 
Back Up Next