007-608, 007-624,  and 007-502, CYANOPROPYLPHENYL METHYLPOLYSILOXANES

 
Up
EQUIVALENTS
007-1
400-1HT
007-5
400-5HT
007-5MS
007-10_20
007-1301
007-624
007-35
007-1701
007-17
007-65HT
007-225
007-CW
007-FFAP
007-23
PLT-5A

007-608, 007-624, and 007-502 offer three variations of cyanopropylphenyl substitutions on a methylpolysiloxane backbone. These phases have been specifically designed for the analysis of volatile organic compounds and pesticides as specified in many EPA Methods including 502.1, 502.2, 503.1, 524.1, 524.2, 601, 602, 608, 624, 8010, 8011, 8015, 8020, 8240, and 8260. By using 007-502 and 007-624 phase types on 0.53mm I.D. columns, the entire range of volatile compounds, including gases, can be analyzed beginning at ambient temperatures.

Bonded and crosslinked
Specifically designed for volatile organic compound analyses
Similar phases: DB-624, DB-1301, Rtx-502, DB-608, VOCOL, RTX-Volatiles, PB-608,
Rtx-35, AT-624, BP-624, CPSil-13CB
USP Phase Specification:  G43
   
007-608, 007-624 and 007-502 Cyanopropylphenyl Methylpolysiloxane columns are most commonly requested in the following
column I.D.'s and column lengths. 
The film thickness ranges are noted in the chart below.
I.D. 30M. 50M. 60M. 75M. 100M. 105M. STANDARD FILM THICKNESS RANGE
0.25mm       1.0 - 3.0µm
0.32mm     1.0 - 5.0µm
0.53mm 0.5 - 5.0µm
 Inquire with tech@quadrexcorp.com about custom lengths and films.
 

007-608, 007-624, and 007-502 OPERATING TEMPERATURE RANGE 

film thickness temperature range
up to 1.0µm -50° C to 325°C
2.0 to 5.0 up to 280°C
   
007-624 Bonded Phase Retention Index
benzene 1-nitropropane 2-pentanone pyridine butanol
684.05

881.36

724.27

793.53

707.78

 

Hot Tip
DON'T SEE A LENGTH OR FILM THICKNESS THAT YOU REQUIRE?

CONTACT US - WE DO CUSTOM CONFIGURATIONS ALL THE TIME!


APPLICATIONS

~CLICK~
BELOW

View 007-502, 007-608,
007-624 chromatograms on the web:

EPA METHOD 502 - DRINKING WATER
DDT ISOMERS
EPA METHOD 608 - PESTICIDES
HERBICIDES
EPA METHOD 524.2- DRINKING WATER
EPA METHOD 601
EPA METHOD 601 - GASES
EPA METHOD 601 - STANDARDS
EPA METHOD 624 - PURGE AND TRAP
RESIDUAL SOLVENTS IN DRUGS
 