007-5, (5% PHENYL) METHYLPOLYSILOXANE

 
Up
EQUIVALENTS
007-1
400-1HT
007-5
400-5HT
007-5MS
007-10_20
007-1301
007-624
007-35
007-1701
007-17
007-65HT
007-225
007-CW
007-FFAP
007-23
PLT-5A

The 007-5 phase is a (5% phenyl) methylpolysiloxane polymer.  Like the 007-1dimethylpolysiloxane phase, the  007-5 phase is a widely used general purpose GC phase ideal for a broad range of applications.  The presence of the phenyl groups provides induced dipole interactions leading to degrees of increased retention for aromatic solutes.  A 5% phenyl substitution causes a nominal increase in polarity;  yet the 007-5 phase displays the attributes of a non-polar phase.  

The non-polar 007-5 phase, which separates compounds according to boiling point, is another frequently used phase type in GC. Bonding and crosslinking this general purpose GC phase increases the resistance to degradation by rinsing, large solvent injections and the deposition of non-volatiles.  The 007-5 phase offers excellent efficiency and thermal stability.  In addition, this non-polar phase is less susceptible to oxidation and hydrolysis than phases incorporating more polar functional groups.  

Bonded and Crosslinked
Non polar
Excellent thermal stability
Comparable to: SE-52, SE-54, OV-73
Similar phases: DB-5, Rtx -5, HP-5, Ultra-5, SPB-5, CPSil-8CB, AT-5, BP-5
USP Phase Specification: G27

007-5 PHATTM Phase Columns
Similar to the 007-1 dimethylpolysiloxane phase, the 007-5 is offered in very thick films as noted below.  In addition to the standard range of column configurations offered with the 007-5 phase type, a new coating technology developed at Quadrex allows us to extend the functional range of columns coated with this phase type by the application of very thick films of the 007-5 phase.  For example, films up to 3.5 microns on 0.10mm I.D. fused silica and 18.0 microns on 0.53mm I.D. fused silica are now possible.  These PHAT PhaseTM thick film columns are ideal for low molecular weight analyses previously performed on packed columns. 

Advantages of PHAT PHASETM fused silica capillary columns include:

greater sample size for trace analyses of very volatile compounds
increased retention of volatile compounds leading to higher elution temperatures

GC analyses of gases and other types of low molecular weight compounds have been traditionally accomplished on packed columns with heavy loadings or adsorbent type columns.  More recently, porous layer open tubular (PLOT) capillary columns have been utilized in the separation of low molecular weight applications despite the drawbacks in using these types of columns such as sample adsorption and bead migration within the column.  

Attempts have been made to use 'thick filmed' wall coated open tubular (WCOT) capillary columns but the films have typically been confined to a maximum of 8.0 microns due to limitations in conventional column coating technology.  While these 'traditional' thick film columns have been used for some for low molecular weight applications, they could not attain the separations and sample loadings that could be achieved on packed columns.  

By employing our proprietary coating technique we are now able to reproducibly manufacture fused silica capillary columns having phase ratios comparable to heavily loaded packed columns.  The PHAT PhaseTM columns are available with 007-1, dimethylpolysiloxane and our 007-5, 5% phenyl methylpolysiloxane phases in lengths up to 30 meters.  These PHAT PhaseTM thick film capillary columns are ideal for low molecular weight analyses previously performed on packed columns.  

The two SEM photomicrographs below are of a 0.53mm I.D. fused silica column coated with 007-1 dimethylpolysiloxane PHAT PhaseTM. Figure 1 (at 142x magnification) clearly shows the internal diameter of the 0.53mm I.D. column and the thick film coated on the internal surface.  Note that the phase coating is similar in thickness to the columns' outer polyimide coating, which is typically 15-20 microns.  

Application areas for these PHAT PhaseTM columns include the analysis of natural gas, auto emissions, light hydrocarbon refinery cuts, amines, alcohols, free fatty acids, refrigerants, residual solvents and air pollutants as defined in the EPA TOC Methods. 

007-5 5% phenyl methylpolysiloxane columns are available in all standard column I.D.'s and lengths. 
The film thickness ranges are noted in the chart below.
I.D. 10M. 15M. 25M. 30M. 50M. 60M. 75M. 100M. STANDARD FILM THICKNESS RANGE
0.10mm         0.1 - 0.5µm
0.18mm       0.1 - 0.5µm
0.25mm 0.1 - 1.0µm
0.32mm 0.1 - 5.0µm
0.53mm 0.1 - 8.0µm
007-5 PHAT TM Phase extra thick film columns
I.D. 10M. 15M. 20M. 25M. 30M.       PHAT PHASE FILM THICKNESS RANGE
0.10mm         1.0 - 3.5µm
0.18mm       1.0 - 6.0µm
0.25mm       2.0 - 5.0µm
0.32mm       6.0 - 12.0µm
0.53mm       10.0 - 18.0µm
 Inquire with tech@quadrexcorp.com about custom lengths and films.
 

007-5 OPERATING TEMPERATURE RANGE 

film thickness temperature range
up to 1.0µm -50° C to 350° C
2.0 to 5.0µm up to 300° C
6.0 to 8.0µm up to 280° C
9.0 to 12.0µm up to 240° C
12.0µm and above up to 200° C
   
007-5 Bonded Phase Retention Index
benzene 1-nitropropane 2-pentanone pyridine butanol

665.62

751.12

689.59

756.23

662.46

Hot Tip
DON'T SEE A LENGTH OR FILM THICKNESS THAT YOU REQUIRE?

CONTACT US - WE DO CUSTOM CONFIGURATIONS ALL THE TIME!


APPLICATIONS

~CLICK~
BELOW

View 007-5 chromatograms on the web:

#2 FUEL OIL
#4 FUEL OIL
#5 FUEL OIL
#6 FUEL OIL
ACRYLATES
ANABOLIC
    STEROIDS
ANESTHETICS
ANTI-
CONVULSANT DRUGS
ANTI-
DEPRESSANTS
CORTI-
COSTEROIDS
EPA METHOD
    505 - ORGANOHALIDE PESTICIDES
EPA METHOD 605 - PHENOLS
EPA OIL ANALYSIS STD.
NATURAL GAS
PEPPER SPRAY
TESTOSTERONE DERIVATIVE STEROIDS
 
Back Up Next
Copyright 2009 QUADREX CORPORATION All rights reserved