The 007-5
phase is a (5% phenyl) methylpolysiloxane polymer.
Like the 007-1dimethylpolysiloxane phase, the
007-5 phase is a widely used general purpose GC
phase ideal for a broad range of applications.
The presence of the phenyl groups provides
induced dipole interactions leading to degrees of
increased retention for aromatic solutes.
A 5% phenyl substitution causes a nominal
increase in polarity; yet the 007-5
phase displays the attributes of a non-polar phase.
The
non-polar 007-5 phase, which separates compounds
according to boiling point, is another frequently used
phase type in GC. Bonding and crosslinking this general
purpose GC phase increases the resistance to degradation
by rinsing, large solvent injections and the deposition
of non-volatiles. The 007-5 phase
offers excellent efficiency and thermal stability.
In addition, this non-polar phase is less
susceptible to oxidation and hydrolysis than phases
incorporating more polar functional groups.
 |
Bonded and
Crosslinked |
 |
Non polar |
 |
Excellent
thermal stability |
 |
Comparable to:
SE-52, SE-54, OV-73 |
 |
Similar
phases: DB-5, Rtx -5, HP-5, Ultra-5,
SPB-5, CPSil-8CB, AT-5, BP-5 |
 |
USP Phase Specification: G27 |
007-5 PHATTM
Phase Columns
Similar to the
007-1
dimethylpolysiloxane phase, the 007-5 is
offered in very thick films as noted below. In addition
to the standard range of column configurations offered
with the 007-5 phase type, a new coating technology
developed at Quadrex allows us to extend the functional
range of columns coated with this phase type by the
application of very thick films of the 007-5 phase.
For example, films up to 3.5 microns on 0.10mm
I.D. fused silica and 18.0 microns on 0.53mm I.D. fused
silica are now possible. These PHAT
PhaseTM thick film columns are ideal for low
molecular weight analyses previously performed on packed
columns.
Advantages
of PHAT PHASETM fused silica capillary
columns include:
 |
greater sample
size for trace analyses of very volatile
compounds
|
 |
increased
retention of volatile compounds leading to
higher elution temperatures
|
GC analyses of gases and
other types of low molecular weight compounds have been
traditionally accomplished on packed columns with heavy
loadings or adsorbent type columns.
More recently, porous layer open tubular (PLOT)
capillary columns have been utilized in the separation
of low molecular weight applications despite the
drawbacks in using these types of columns such as sample
adsorption and bead migration within the column.
Attempts have been made to use 'thick filmed' wall
coated open tubular (WCOT) capillary columns but the
films have typically been confined to a maximum of 8.0
microns due to limitations in conventional column
coating technology. While these
'traditional' thick film columns have been used for some
for low molecular weight applications, they could not
attain the separations and sample loadings that could be
achieved on packed columns.
By
employing our proprietary coating technique we are now
able to reproducibly manufacture fused silica capillary
columns having phase ratios comparable to heavily loaded
packed columns. The PHAT PhaseTM
columns are available with 007-1, dimethylpolysiloxane
and our 007-5, 5% phenyl methylpolysiloxane phases in
lengths up to 30 meters. These PHAT
PhaseTM thick film capillary columns are
ideal for low molecular weight analyses previously
performed on packed columns.
The two SEM photomicrographs below are of a 0.53mm I.D.
fused silica column coated with 007-1
dimethylpolysiloxane PHAT PhaseTM. Figure 1
(at 142x magnification) clearly shows the internal
diameter of the 0.53mm I.D. column and the thick film
coated on the internal surface. Note
that the phase coating is similar in thickness to the
columns' outer polyimide coating, which is typically
15-20 microns.
Application areas for these PHAT PhaseTM
columns include the analysis of natural gas, auto
emissions, light hydrocarbon refinery cuts, amines,
alcohols, free fatty acids, refrigerants, residual
solvents and air pollutants as defined in the EPA TOC
Methods.
007-5 5% phenyl methylpolysiloxane columns are available
in all standard column I.D.'s and lengths.
The film thickness ranges are noted in the
chart below. |
|
I.D. |
10M. |
15M. |
25M. |
30M. |
50M. |
60M. |
75M. |
100M. |
STANDARD
FILM THICKNESS RANGE |
|
0.10mm |
 |
 |
 |
 |
|
|
|
|
0.1 -
0.5µm |
|
0.18mm |
 |
 |
 |
 |
 |
|
|
|
0.1 -
0.5µm |
|
0.25mm |
 |
 |
 |
 |
 |
 |
 |
 |
0.1 -
1.0µm |
|
0.32mm |
 |
 |
 |
 |
 |
 |
 |
 |
0.1 -
5.0µm |
|
0.53mm |
 |
 |
 |
 |
 |
 |
 |
 |
0.1 -
8.0µm |
|
007-5 PHAT TM Phase extra thick
film columns |
|
I.D. |
10M. |
15M. |
20M. |
25M. |
30M. |
|
|
|
PHAT PHASE
FILM THICKNESS RANGE |
|
0.10mm |
 |
 |
 |
 |
|
|
|
|
1.0 -
3.5µm |
|
0.18mm |
 |
 |
 |
 |
 |
|
|
|
1.0 -
6.0µm |
|
0.25mm |
 |
 |
 |
 |
 |
|
|
|
2.0 -
5.0µm |
|
0.32mm |
 |
 |
 |
 |
 |
|
|
|
6.0 -
12.0µm |
|
0.53mm |
 |
 |
 |
 |
 |
|
|
|
10.0 -
18.0µm |
|
Inquire with
tech@quadrexcorp.com
about custom lengths and films. |
|
007-5 OPERATING TEMPERATURE RANGE |
|
film thickness |
temperature range |
|
up to 1.0µm |
-50° C to 350° C |
|
2.0 to 5.0µm |
up to 300° C |
|
6.0 to 8.0µm |
up to 280° C |
|
9.0 to 12.0µm |
up to 240° C |
|
12.0µm
and above |
up to 200° C |
|
|
|
|
007-5 Bonded Phase Retention Index |
|
benzene |
1-nitropropane |
2-pentanone |
pyridine |
butanol |
|
665.62 |
751.12 |
689.59 |
756.23 |
662.46 |
|